They are available with fixed or removable tube bundles, Fied tube bundled units are available in a
tube-side one pass, two pass or four passes.
Removable tube bundle units are available in in tube-side one or two passes. Two baffle designs are available, “O” – close
baffle spacing with higher efficiency and higher pressure drops, and “W” with
wider baffle spacing to accommodate lower pressure drop requirements. 
xchanger surfaces from 0.15 m2 - 4.00 m2 can be installed
in fixed and graduated building sizes.The highly efficient spin-shaped oil flow
on the shell side is generated by the special helical screws. The helical pitch can be adapted to the flow
quantity. Two versions are available: “O”
- low helical screw pitch for liquid oils.
And “W” - - high helical screw
pitch for viscid oils providing a compromise between an optimum heat transfer
and pressure drops.